1) check the outside and inside of the hopper before and after each extruder, check
whether the fastening bolts are loose, the safety cover is firm, the position of
each button switch is correct, and then the lubricating oil is added to the
lubricating parts, and the cleaning and health work of the equipment is done well.
2) notify staff around equipment when preparing to drive.
3) low speed starting
drive screw motor, check the main motor working ampere meter pointer swing is
normal, if the equipment operation has abnormal sound or screw operation is not
stable phenomenon, should stop immediately, find the relevant personnel maintenance
and solution.
4) the screw is not allowed to exceed 3min by air transport to the
test car. All the normal installation dies, the installation of the mould with the
connecting bolt, the use of a layer of molybdenum disulfide or silicone oil before
use, in order to facilitate disassembly.
5) at the initial stage of the feeding
production, the screw uses the minimum working speed, and the material should be
less and even. At any time, there is no abnormal change in the oscillating change
of the working current meter pointer of the motor.
6) after the extruder is put into
normal production, the operator should check the temperature changes of the bearing
parts frequently. When examining the temperature of motor and bearing parts, gently
contact the examination site with the back of the fingers. No rotating parts should
be touched by hand when the equipment is running.
7) when dismantling and installing
screws and moulds, it is not allowed to percussion parts directly with heavy
hammers. If necessary, hardwood should be knocked down for demolition or
installation.
8) when cleaning the screw, cylinder and mould residue, it must be
cleaned with bamboo or copper knives and brushes. No steel tools should be used to
scrape scraps or barbecue parts.
9) when the extruder fails, the extruder is not
allowed to run. When the extruder screw is rotated and the die is adjusted, the
operator is not allowed to face the outlet of the extruding cylinder so as to
prevent accidents.
10) when the extruder is working, the operator is not allowed to
leave the post. If he has to leave, the extruder should be stopped.
11) remove the
screw after parking. After the debris is cleaned, use a layer of antirust oil. If
temporarily unused, it should be wrapped and hung vertically in the dry and
ventilated place.
12) the extruders and moulds that are not used for a long time to
stop production should be coated with antirust oil to seal the entry and exit ports
so as to prevent foreign objects from entering.
Service hotline: +86-0536-2181073
Email: sales@goldsione.com
Address:WeiFang, ShanDong, China